Defibrillator Monitor

Defibrillator Monitor

Defibrillators benefit patients who experience a sudden case of heartbeat is arrhythmias. In these instances defibrillators are an important tool for anyone in the vicinity of a victim suffering from ventricular arrhythmia.

 

Display

  • Screen Type: High-resolution display
  • Screen Size: 7 inches (17.7 cm) diagonally
  • Sweep Speed: 25mm/sec
  • Information: Heart Rate .  Lead/Pads.  Alarm .  On/Off  . SpO2 .  AED
  • Functions and Prompts Alarm Selection and Limits Delivered Energy

 
Defibrillator

  • Waveform: Biphasic (BTE)
  • Charge Time: Less than 7 seconds with a new fully charged battery
  • Energy Display: Monitor display indicates both selected and delivered energy
  • Charge Prompt Type: Voice and visual prompts
  • Electrode Impedance Measurement Range: 0-250 ohms

 
ECG Monitoring

  • Patient Connection: 3-lead ECG cable or 5-lead ECG cable paddles
  • Lead Selection: Displayed on monitor paddles I II III AVR AVL AVF V
  • ECG Size: 0.25 0.5 1 1.5 2 4 cm/mV display on monitor
  • Heart Rate: 20-300BPM
  • Heart Rate Alarm: On/Off displayed on monitor user-selectable
  • Smart Alarms: Beeper/voice prompts indicate shock able rhythm

 
Battery

  • Type: Rechargeable Ni-MH battery 12V
  • Operating time: For a new fully charged battery: 60 defibrillator discharges at maximum energy or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.

 
SpO2 Module (Options):

  • Measurement Range: 30~100% ±2% between 80%~90% others ±5%
  • Alarm Range: User set high limit and low limit.
  • Alarm Accuracy: ±10% within setting values.
  • Alarm time Accuracy: less than 12 sec.
  • 1-Meditech Pulse Oximeter
  • 2-Nellcor Pulse Oximeter

 
EtCO2 Module (Options):

  • CO2 Range 0 to 13%(0-98.8mmHg@BTPS)
  • Breath Rate 3~60 BPM
  • Measurement Accuracy ±1BPM 

 
Pacemaker (Options):

  • Type: VVI
  • Pulse Type: rectangular,constant current
  • Pulse Amplitude: 0 to 180 mA ± 10% or 5 mA (whichever is greater).
  • Pacing Rate: Variable from 30 ppm to 180 ppm ±1.5% (increments or decrements by a value of 2 ppm)
  • Multi-Function Electrode: (MFE) Pads: multipurpose defibrillation/pacing electrodes
  • Pause: Pacing pulse frequency reduced by a factor of 4 when activated
  • Refractory Period: NC(VVI demand do not have this specification)
  • Pulse Width: (20+ 1.5 ms)
  • Output Protection: Fully defibrillator protected and isolated

 
Recorder

  • Paper: 50mm thermal
  • Speed: 12.5mm/sec 25mm/sec 50mm/sec. User-selectable 6-second delay
  • Printing Method: High-resolution thermal print head
  • Print-out Modes: Manual or automatic user-configurable
  • On/Off Control: Front panel and paddle
  • Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge

 
AED Mode

  • AED Function: Auto analyze and charge x3 with programmable auto energy level selection screen prompts and voice prompts
  • Shockable Rhythms: Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm and QRS complex wave duration >=140ms
  • Charge Control: Control on device front panel press key on paddle
  • Prompts: Voice and visual prompts

 
Manual Mode

  • Energy Selection: Selectable at 2 5 7 10 20 30 50 70 100 150 200 300 360 joules.
  • Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.